181 research outputs found

    Theoretical Reflections on the Underutilization of Employee Talents in the Workplace and the Consequences

    Get PDF
    This article describes "chronic relative underperformance" (CRU)-a special example of P-E misfit. It investigates literature on giftedness, underachievement, underemployment, workplace boredom, and boreout, and connects these to clinical psychological views on mentalization. The intent is to develop thoughts that are useful in the understanding of why some employees fail to thrive, even though they are performing seemingly well enough as regards to the targets of the employer, and offer a frame of reference that can lead to further understanding of this condition. CRU is an issue that is hardly described within the literature. Recognizing CRU in the workforce and taking steps to counter its effects may lead to a more efficient and elegant way to reach organizational, and personal, goals

    Prevalence and determinants of intravenous admixture preparation errors:A prospective observational study in a university hospital

    Get PDF
    Background Intravenous admixture preparation errors (IAPEs) may lead to patient harm. Insight into the prevalence as well as the determinants associated with these IAPEs is needed to elicit preventive measures. Aim The primary aim of this study was to assess the prevalence of IAPEs. Secondary aims were to identify the type, severity, and determinants of IAPEs. Method A prospective observational study was performed in a Dutch university hospital. IAPE data were collected by disguised observation. The primary outcome was the proportion of admixtures with one or more IAPEs. Descriptive statistics were used for the prevalence, type, and severity of IAPEs. Mixed-effects logistic regression analyses were used to estimate the determinants of IAPEs. Results A total of 533 IAPEs occurred in 367 of 614 admixtures (59.8%) prepared by nursing staff. The most prevalent errors were wrong preparation technique (n = 257) and wrong volume of infusion fluid (n = 107). Fifty-nine IAPEs (11.1%) were potentially harmful. The following variables were associated with IAPEs: multistep versus single-step preparations (adjusted odds ratio [OR(adj)] 4.08, 95% confidence interval [CI] 2.27–7.35); interruption versus no interruption (OR(adj) 2.32, CI 1.13–4.74); weekend versus weekdays (OR(adj) 2.12, CI 1.14–3.95); time window 2 p.m.-6 p.m. versus 7 a.m.-10 a.m. (OR(adj) 3.38, CI 1.60–7.15); and paediatric versus adult wards (OR(adj) 0.14, CI 0.06–0.37). Conclusion IAPEs, including harmful IAPEs, occurred frequently. The determinants associated with IAPEs point to factors associated with preparation complexity and working conditions. Strategies to reduce the occurrence of IAPEs and therefore patient harm should target the identified determinants

    Effect of a Pharmacy-based Centralized Intravenous Admixture Service on the Prevalence of Medication Errors:A Before-and-After Study

    Get PDF
    Intravenous admixture preparation errors (IAPEs) may lead to patient harm. The primary aim of this study was to assess the effect of a pharmacy-based centralized intravenous admixture service (CIVAS) on IAPEs. METHODS: We conducted a before-and-after study in 3 clinical wards before CIVAS implementation and in the CIVAS unit 18 months after implementation. Intravenous admixture preparation error data were collected by disguised observation. The primary outcome was the proportion of admixtures with 1 or more IAPEs. Secondary outcomes were the type and potential severity of IAPEs, noncompliance to hygiene procedures, and nursing staff satisfaction with the CIVAS. The primary outcome was analyzed using a multivariable mixed-effects logistic regression model. RESULTS: One or more IAPEs were identified in 14 of 543 admixtures (2.6%) in the CIVAS unit and in 148 of 282 admixtures (52.5%) in the clinical wards (odds ratio, 0.02; 95% confidence interval, 0.004–0.05). The most common IAPE types were wrong solvent or diluent (n = 95) and wrong volume of infusion fluid (n = 45). No potentially harmful IAPEs occurred in the CIVAS unit as opposed to 22 (7.8%) in the clinical wards. Disinfection procedures were better adhered to in the CIVAS unit. Overall nurse satisfaction with the CIVAS increased from a median of 70 (n = 166) 5 months after intervention to 77 (n = 115) 18 months after intervention (P < 0.001) on a 100-point scale. CONCLUSIONS: Centralized intravenous admixture service performed notably better than the clinical wards with regard to IAPEs and noncompliance to hygiene procedures. Nurses were satisfied with the CIVAS. Hence, the implementation of CIVAS is an important strategy to improve medication safety in hospitals

    Four-year clinical outcome following randomised use of zotarolimus-eluting stents versus everolimus-eluting stents in all-comers: Insights from the DUTCH PEERS trial

    Get PDF
    Background: The DUTCH PEERS (TWENTE II) trial (clinicaltrials.gov NCT01331707) is a randomised, multicenter, single-blinded, investigator initiated all-comers trial. All coronary syndromes were permitted with no limit for lesion length, reference size, or number of lesions or diseased vessels to be treated. In total, 1811 patients were 1:1 randomised to cobalt chromium-based zotarolimuseluting stents (ZES) versus platinum chromium-based everolimus-eluting stents (EES). These durable polymer-based drug-eluting stents (DES) were developed to facilitate device deliverability and to improve stent apposition to the vessel wall. Purpose: We assessed the 4-year clinical outcome of the DUTCH PEERS trial in terms of safety and efficacy. Methods: Clinical outcome was assessed by means of follow-up data of the trial participants. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction (MI) or target vessel revascularization. Secondary endpoints included the individual components of the TVF and the incidence of definite-or-probable stent thrombosis. Endpoints were analyzed by the logrank test by comparing the time to the endpoint, using the Kaplan-Meier method. Independent contract research organizations performed the study monitoring and clinical event adjudication. Results: The 4-year clinical follow-up data were available in 1802 patients (99.5%; 4 patients were lost to follow-up and 5 withdrew consent). The ZES and EES groups showed favourable outcomes with a similar incidence of TVF (12.1% vs. 12.1%; Logrank p=0.95). The rates of the individual components of TVF were also similar for both stent arms: cardiac death (3.9% vs. 3.7%; Logrank p=0.78); target vessel-related MI (3.2% vs. 2.5%; Logrank p=0.38); and target vessel revascularization (6.8% vs. 7.5%; Logrank p=0.55), respectively. In addition, the incidence of definite-or-probable stent thrombosis was similar for patients treated with ZES versus EES (1.5% vs. 1.2%; Logrank p=0.67). Conclusion: At 4-year follow-up, ZES and EES showed similar and sustained results in terms of safety and efficacy for treating all-comer patients

    Symptomatic relief precedes improvement of myocardial blood flow in patients under spinal cord stimulation

    Get PDF
    BACKGROUND: Spinal cord electrical stimulation (SCS) has shown to be a treatment option for patients suffering from angina pectoris CCS III-IV although being on optimal medication and not suitable for conventional treatment strategies, e.g. CABG or PTCA. Although many studies demonstrated a clear symptomatic relief under SCS therapy, there are only a few short-term studies that investigated alterations in cardiac ischemia. Therefore doubts remain whether SCS has a direct effect on myocardial perfusion. METHODS: A prospective study to investigate the short- and long-term effect of spinal cord stimulation (SCS) on myocardial ischemia in patients with refractory angina pectoris and coronary multivessel disease was designed. Myocardial ischemia was measured by MIBI-SPECT scintigraphy 3 months and 12 months after the beginning of neurostimulation. To further examine the relation between cardiac perfusion and functional status of the patients we measured exercise capacity (bicycle ergometry and 6-minute walk test), symptoms and quality of life (Seattle Angina Questionnaire [SAQ]), as well. RESULTS: 31 patients (65 ± 11 SEM years; 25 male, 6 female) were included into the study. The average consumption of short acting nitrates (SAN) decreased rapidly from 12 ± 1.6 times to 3 ± 1 times per week. The walking distance and the maximum workload increased from 143 ± 22 to 225 ± 24 meters and 68 ± 7 to 96 ± 12 watt after 3 months. Quality of life increased (SAQ) significantly after 3 month compared to baseline, as well. No further improvement was observed after one year of treament. Despite the symptomatic relief and the improvement in maximal workload computer based analysis (Emory Cardiac Toolbox) of the MIBI-SPECT studies after 3 months of treatment did not show significant alterations of myocardial ischemia compared to baseline (16 patients idem, 7 with increase and 6 with decrease of ischemia, 2 patients dropped out during initial test phase). Interestingly, in the long-term follow up after one year 16 patients (of 27 who completed the one year follow up) showed a clear decrease of myocardial ischemia and only one patient still had an increase of ischemia compared to baseline. CONCLUSION: Thus, spinal cord stimulation not only relieves symptoms, but reduces myocardial ischemia as well. However, since improvement in symptoms and exercise capacity starts much earlier, decreased myocardial ischemia might not be a direct effect of neurostimulation but rather be due to a better coronary collateralisation because of an enhanced physical activity of the patients

    TCT-588 2-Year Clinical Outcome of the Randomized, Multicenter DUTCH PEERS (TWENTE II) Trial, Comparing Cobalt-Chromium Zotarolimus-Eluting Resolute Integrity Stents and Platinum-Chromium Everolimus-Eluting Promus Element Stents in “All-Comer” Patients

    Get PDF
    Background: The multicenter, prospective, randomized, single-blinded, investigator-initiated DUTCH PEERS (TWENTE II) “All Comers” Trial demonstrated at 1-year follow-up the non-inferiority of third-generation Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, CA) versus Promus Element everolimus-eluting stents (Boston Scientific, Natick, MA), based on a similar incidence of the primary endpoint target vessel failure (TVF), a composite of cardiac death, target vessel revascularization (TVR), or myocardial infarction (MI). No other follow-up data beyond 12 months have been published from a randomized head-to-head comparison of both stents. Methods: In 4 study centers in the Netherlands, 1,811 patients were 1:1 randomly assigned to treatment with one of both stents. Patients with any clinical syndrome, any lesion type, and any number of lesions or vessels to be treated were included. Study monitoring and clinical event adjudication were performed by two independent Dutch contract research organizations (Diagram, Zwolle, and Cardialysis, Rotterdam, respectively). Results: DUTCH PEERS examines an all-comer patient population that included 59% of patients with acute coronary syndromes (20% of all patients presented with an acute STEMI) and 66% of patients with complex target lesions. We will compare for both stent groups the 2-year incidence of TVF (primary endpoint) and various secondary endpoints, including individual components of the primary endpoint, the incidence of stent thrombosis, and other composite endpoints, such as target lesion failure, major adverse cardiac events, and the patient-oriented composite endpoint. In addition, we will report the outcome of patients with longitudinal stent deformation after discontinuation of dual anti-platelet therapy. Conclusions: Clinical outcome of the DUTCH PEERS trial at 2-year follow-up will be presented

    Acute success and short-term follow-up of catheter ablation of isthmus-dependent atrial flutter; a comparison of 8 mm tip radiofrequency and cryothermy catheters

    Get PDF
    Objectives: To compare the acute success and short-term follow-up of ablation of atrial flutter using 8 mm tip radiofrequency (RF) and cryocatheters. Methods: Sixty-two patients with atrial flutter were randomized to RF or cryocatheter (cryo) ablation. Right atrial angiography was performed to assess the isthmus. End point was bidirectional isthmus block on multiple criteria. A pain score was used and the analgesics were recorded. Patients were followed for at least 3 months. Results: The acute success rate for RF was 83% vs 69% for cryo (NS). Procedure times were similar (mean 144±48 min for RF, vs 158±49 min for cryo). More applications were given with RF than with cryo (26±17 vs. 18±10, p<0.05). Fluoroscopy time was longer with RF (29±15 vs. 19±12 min, p<0.02). Peak CK, CK-MB and CK-MB mass were higher, also after 24 h in the cryo group. Troponin T did not differ. Repeated transient block during application (usually with cryoablation) seemed to predict failure. Cryothermy required significantly less analgesia (p<0.01), and no use of long sheaths (p<0.005). The isthmus tended to be longer in the failed procedures (p=0.117). This was similar for both groups, as was the distribution of anatomic variations. Recurrences and complaints in the successful patients were similar for both groups, with a very low recurrence of atrial flutter after initial success. Concl
    corecore